APPA 51 Thermometer K-typeSummary APPA 51
- Measuring type: K-type thermocouple
- Measurement range: -50~1300°C
- Additional Features: display hold function
- K-type Thermocouple
- Large LCD display (18.5mm)
- 1°C or 0.1°C (1°F or 0.1°F) resolution; °C or °F resolution
- Maximum Record; Reading hold function
- Standard 9V battery; Protective holster with tilt stand
- Bead probe included
Specifications
Specifications
|
APPA 51
|
APPA 52
|
APPA 53II
|
APPA 55II
|
|
Measurement Range: | K-type, -50°C~1300°C, -58°F~1999°F |
+
|
+
|
N/A
|
N/A
|
K-type, -200°C~1372°C, -328°F~2501°F |
N/A
|
N/A
|
+
|
+
|
|
J-type, -210°C~1200°C, -346°F~2192°F | |||||
Resolution: | High: 0.1°C or 0.2°F, Low: 1°C or 1°F |
+
|
+
|
N/A
|
N/A
|
0.1°C/0.1 K/0.2°F < 1000° , 1°C/1 K/2°F < 1000° |
N/A
|
N/A
|
+
|
+
|
|
K-type Accuracy: | ±(0.3%+1°C) at -50°C~1000°C, ±(0.3%+2°F) at -58°F~1832°F |
+
|
+
|
N/A
|
N/A
|
±(0.5%+1°C) at 1000-1300°C, ±(0.5%+2°F) at 1832°F~1999°F | |||||
±(0.3%+1°C) at -200°C~-100°C, ±(0.3%+2°F) at -328°F~-148°F |
N/A
|
N/A
|
+
|
+
|
|
±(0.1%+0.7°C) at -99.9°C~999.9°C, ±(0.1%+1.4°F) at-147.8°F~999.9°F | |||||
±(0.3%+1°C) at 1000°C—1372°C, ±(0.3%+2°F) at 1000°F~2501°F | |||||
J-type Accuracy: | ±(0.3%+1.1°C) at -210°C~-100°C, ±(0.3%+2.2°F) at -346°F~-148°F |
N/A
|
N/A
|
+
|
+
|
±(0.1%+0.8°C) at -99.9°C~999.9°C, ±(0.1%+1.6°F) at-147.8°F~999.9°F | |||||
±(0.3%+1°C) at 1000°C~1200°C, ±(0.3%+2°F) at 1000°F~2192°F | |||||
Accuracy: | T1-T2 |
N/A
|
+ (K-type)
|
N/A
|
+ (K/J-type)
|
±(0.3% of T1-T2 reading + 2.0°C), ±(0.3% of T1-T2 reading + 4.0°F) | |||||
Temperature Coefficient: | 0.15(Spec. Acc)/°C, <18°C or >28°C |
+
|
+
|
N/A
|
N/A
|
0.1(Spec. Acc)/°C, <18°C or >28°C |
N/A
|
N/A
|
+
|
+
|
|
Data logging Capacity: | 16,000 records |
N/A
|
N/A
|
+
|
+
|
PC interface software: | Optical RS-232 interface cable with Win DTM 50 software |
N/A
|
N/A
|
+ (Option)
|
+ (Option)
|
General
|
APPA 51
|
APPA 52
|
APPA 53II
|
APPA 55II
|
Input: K-type thermocouple |
+
|
+
|
+ (J-type option)
|
+ (J-type option)
|
Sampling Rate: 2.5 times/sec |
+
|
+
|
2 times/sec
|
1 times/sec
|
Display: 3 digit (1999 count) LCD, full annunciators |
+
|
+
|
N/A
|
N/A
|
Display: Triple 4 digit (9999 count) LCD, full annunciators |
N/A
|
N/A
|
+
|
+
|
Overload Indication |
"1" or "-1"
|
"1" or "-1"
|
"----"
|
"----"
|
Low Battery Indication |
+
|
+
|
+
|
+
|
Selectable Auto Power Off: you can select an APO of OFF, 10, 20, 30, 40, 50 and 60 minutes |
N/A
|
N/A
|
+
|
+
|
Operating Temperature: 0°C~50°C, ≤80% RH |
+
|
+
|
+
|
+
|
Storage Temperature: -20°C~60°C |
+
|
+
|
+
|
+
|
Input Protection: 60V DC or 24Vrms AC maximum |
+
|
+
|
+
|
+
|
Power Requirement: Single 9V battery (NEDA 1604 or IEC 6F22) |
+
|
+
|
+
|
+
|
Battery Life: in hours (Alkaline battery) |
250
|
250
|
90
|
90
|
Size: 64mm(W) x 160mm (L) x 26 mm(H), without holster |
+
|
+
|
+
|
+
|
Size: 74mm(W) x 170mm (L) x 39 mm (H), with holster |
+
|
+
|
+
|
+
|
Weight: in grams (with holster) |
430
|
430
|
430
|
430
|
Included with instrument: Type 50BK bead thermocouple, ZnC battery (installed), Protective holster, belt clip and manual |
+
|
+
(50BK x 2) |
+
|
+
(50BK x 2) |
Scope of delivery APPA 51
- Thermometer K-type thermocouple APPA 51
- Type 50BK bead thermocouple
- ZnC battery (installed)
- Protective holster
- Belt clip
- Manual